SEMICOSIL® 942 UV A/B

SEMICOSIL® 942 UV A/B is a sprayable, addition-curing, 2-part silicone rubber of low viscosity that cures extremely fast after activation by UV light exposure to a soft conformal coating.



Eigenschaften

  • coating and encapsulant for printed circuit boards
  • dispensing and spraying applications
  • two-part, 10 : 1 mixing ratio
  • low viscosity, shear thinning
  • extremely fast curing at room temperature (after UV-activation)
  • shadow curing at room temperature
  • offers process control option by UV-light (contains UV-tracer)
  • low and constant moduli (-40°C to +180°C) [storage Modulus 10 kPa, 1Hz/25°C]
  • protection of housed PCBs with cover (sticky gel)
  • IEC 60664-3:2017 compliant, positive SIR testing (electromigration free)
  • IPC-CC-830C compliant
  • low ion content (Cl-, Na+, K+, Li+, each <= 2 ppm)

        


To ensure homogeneity component A must be stirred thoroughly before processing.

Surface preparation All surfaces must be clean and free of contaminants that will inhibit the cure of SEMICOSIL® 942 UV A/B. Examples of inhibiting contaminants are sulfur containing materials, plasticizers, urethanes, amine containing materials and organometallic compounds – especially organotin compounds. If a substrate’s ability to inhibit cure is unknown, a small scale test should be run to determine compatibility.


Handling

The A-component contains an UV-tracer that is dispersed in the silicone. The UV-tracer may be subject to a limited sedimentation. In order to guarantee homogenous product performance (curing time, UV-tracability) it is recommended to homogenize the A-side prior to application by stirring.


Mixing

Component B of SEMICOSIL® 942 UV A/B contains an organometallic and a platinum catalyst, component A the crosslinker. Even traces of the catalyst may cause gelling of the component containing the crosslinker. Therefore tools (spatula, stirrers, etc.) used for handling the catalyst component or the catalyzed compound must not come into contact with this component. The two components should be thoroughly mixed at a 10 : 1 ratio by weight or volume. To eliminate any air introduced during dispensing or trapped under components or devices a vacuum encapsulation is recommended.

Curing For the curing an UV lamp (Fe-lamp, D-bulb) with an emission between 250 and 350 nm can be used. It is recommended not to use lamp systems that emit light with a wavelength below 250 nm.
1 space line

Curing time of SEMICOSIL® 942 UV A/B is highly dependent on UV-activation, Significant differences in curing time are obtained for curing different layer thicknesses and for using different substrate materials. Typical values are given below.

UV-activation Curing time (140 mW/cm²) at 25°C (2mm) 1 s 5 min 5 s 2 min 20 s cured after 20 s UV

Without UV-activation SEMICOSIL® 942 UV A/B cures at room temperature within 48 h at 70 °C within 15 min.

SEMICOSIL®  942 UV A/B  is intended to be used only for processing in dispensing equipment configurations with direct mixing of SEMICOSIL®  942 UV A and B  in the mixing tube (.i.e. after the dispensing head). It is not intended to be applied in premixes that are stored in separate reservoirs or distribution systems. Pot-Life after mixing has to be considered.

All surfaces must be clean and free of contaminants that will inhibit the cure of the 10:1 mixture of SEMICOSIL® 942 UV A/B . 

Examples of inhibiting contaminants are sulfur containing materials, plasticizers, urethanes, amine containing materials and organometallic compounds – especially organotin compounds. If a substrate’s ability to inhibit cure is unknown, a small scale test should be run to determine compatibility.

SEMICOSIL 942 ® UV B is supplied in specific packagings allowing the material transfer to reservoirs of state-of-the art dispensing equipment without exposure to ambient light. For this purpose a reusable opening fixture is mounted on the can closure Informations can be provided by the regional sales managers.

To ensure homogenity of the corresponding A component, usually the addition curing silicone SEMICOSIL® 942 UV A must be stirred thoroughly before processing. Typically also SEMICOSIL® 942 UV B  is stirred in the reservoir of the dispensing machine. Dissolved air is removed by standard degassing of reservoir contents.

After exposure to ambient light or daylight SEMICOSIL® 942 UV B should be immediately processed and not stored any longer.

SEMICOSIL® 942 UV B  contains the organometallic UV active catalyst,  the corresponding component A the crosslinker. Even traces of the  catalyst may cause gelling of the component containing the crosslinker. Therefore tools (spatula, stirrers, etc.) used for handling the catalyst-containing component or the catalyzed compound must not come into contact with this component.

SEMICOSIL®  942 UV A  should be  thoroughly mixed with SEMICOSIL®  942 UV B at a  10 : 1 ratio  by weight or volume. Typically static mixing with tube configurations 24/6 or higher (increased no. helical turnings or lower diameter) are sufficient.

To eliminate any air introduced during dispensing or trapped under components or devices a subsequent vacuum encapsulation may be recommended.

UV Irradition on SEMICOSIL® 942 UV B activates the UV-active catalyst. In combination with SEMICOSIL® 942 UV A a very fast cure can be achieved. Cure speed can be tuned in typical ranges between  minutes and  seconds depending on UV Intensity and dose.

Direct Cure: Reaction proceeds after end of UV irradition. Main cure is rapidly  achieved for those areas irradiated with UV light.

Shadow Cure: areas not directly accessible are cured on longer time scale by second addition curing mechanism (see gel time no irradiated)

For the curing an UV lamp (Fe-lamp, D-bulb) with an emission between 250 and 350 nm can be used. It is recommended not to use lamp systems that emit light with wavelengths below 250 nm. An high power UV-LED may also be used (365 nm) for applications allowing minimum distance to the light source. As light penetration depth is reduced  365 nm in UV-LED in comparison with discharge lamp pretests are recommendable to check feasibility for specific application.

Curing time of SEMICOSIL® 942 UV A/B  (10:1) is highly dependent on UV-activation. Significant differences in curing time are obtained for curing different layer thicknesses and for using different substrate materials.

Lagerung

General recommendations SEMICOSIL® 942 UV A/B should be stored in the original light-tight container. After exposure to daylight or UV-light the material should be immediately processed and not stored any longer. The 'Best use before end' date of each batch is shown on the product label. Storage beyond the date specified on the label does not necessarily mean that the product is no longer usable. In this case however, the properties required for the intended use must be checked for quality assurance reasons.

Vertrieb & Support

Wacker Chemie AG
Heilbronner Strasse 74
70191 Stuttgart
Deutschland
+49  711  61942-0 (Phone)
Kontakt

Wie können wir Ihnen helfen?

  • Benötigen Sie Unterstützung bei der Produktauswahl oder wünschen Sie eine technische Beratung? Kontaktieren Sie unsere Experten.
Frage stellen

Bestellen

Meine Medien


Meine Favoriten

Meine Produkte