LC 707 unfilled

WACKER® LC 707 is a one-part, neutral silicone sealant with outstanding adhesion to most building substrates. specially, it is a product for exclusive use of exterior joint because weather resistance and durability is excellent. The movement allowance is about ±25%.         



Eigenschaften

  • solvent free
  • non sag
  • excellent anti-mold
  • ready gunability at lowe(+5 °C) and high(+40 °C) temp.
  • lower-modules 
  • godd adhesion with various materials
  • excellent weather resistance

Disclaimer

Alle unsere Angaben beruhen auf bestem Wissen. Allerdings übernehmen wir hierfür keine Haftung oder Gewährleistung und behalten uns jederzeit technische Änderungen vor. Es liegt in der eigenen Verantwortung des Käufers, die Angaben sowie die Geeignetheit unseres Produktes für den vorgesehenen Einsatzzweck vor dem Gebrauch zu überprüfen. Vertragliche Regelungen gehen immer vor. Der Gewährleistungs- und Haftungsausschluss gilt - insbesondere im Ausland - auch im Hinblick auf Schutzrechte Dritter.

Application processing

Preparation

The substrate areas that will be in contact with          the sealant must be clean, dry and free of all loose   material such as dust, dirt, rust, oil and other contaminants.

Non-porous substrates should be cleaned with a solvent and clean, lint-free, cotton cloth. remove residual solvent before it evaporates with a fresh clean, dry cloth.

For application from cartridges cut thread open, fix nozzle on top and cut to required bead size.

The sealant can be applied in beads or layers. It requires moisture in order to cure.

Masking

To avoid contamination and damage, use masking tape on the side of joint area.

Primer

Deopandion on substance, LC 6692 Primer is strongly recommended. Brush at least 1~2 times on non-porous surface and 2~3 times on porous surface.

Sealing & Tooling

Fully fill in cross point or side edge point of the joint without empty space without bubbles.

Tooling must be done before curing of on the surface is finished. spread sealant with proper spatula.

Removing masking tape & Curing

Get rid of masking tape and clean up remained sealant. Protect from dust and pollutant to have qualified surface and Avoid being shocked and contact on the surface of sealant while curing

Certificate

KS F 4910 F-25LM

Eco-label certificate

Restricion on use

It is the user's responsibility to test the compatibility of the sealant with the adjoining materials. Incompatible substances like coating materials (paints, varnishes and glazes) or organic plasticizer containing rubbers (EPDM, butyl and neoprene) can lead to discoloration or other impairments like loss of adhesion of the sealant. Materials in direct contact with the applied sealant like cleaning agents and materials in indirect contact like gaseous emissions can damage the sealant in its function or change its appearance. Because of the multitude of these materials. Wacker cannot make a general statement to the compatibility of materials with the sealant. In case of doubt the user shall conduct appropriate preliminary tests.

The time until complete curing may be extended at lower temperature, lower humidity, increasing film thickness or by lowvolume of air exchange.
The use of tooling agents should be avoided if possible. Otherwise, water or a diluted solution of a little neutral soap oralcohol in water should be sparingly applied.
LC 707 must not be used for insulating glass applications.
LC 707 should not be used in contact with metals such as lead, copper, brass or zinc due to corrosion.
LC 707 may be discolored in contact with some organic elastomers, e.g. EPDM, APTK and neoprene.
LC 707 should not be used for sealing of aquaria.
LC 707 is not recommended for use on natural stone, such as marble, granite, quartzite, as it can cause
staining.

LC 707 is not recommended for structural glazing bonding.
LC 707 should not be used in contact with metals such as lead, copper, brass or zinc due to corrosion.
LC 707 is not recommended for sealing of aquaria or for longer-term use under water.
LC 707 is not suitable for food grade applications where the joints are likely to come in contact with food.
LC 707 is not suitable for use as a mirror adhesive.
 

Verpackung / Gebinde

Cartridge: 300ml (25ea/1box)

Drum: 200kg

Shelf life

 - 12 months from production date for Cartridge

 - 24 months from produtction date for Drum

 

Lagerung

Should use before the expire day.

Avoid sun light, dry and cool at 5~30 °C is recommended.

Vertrieb & Support

Wacker Chemie AG
Heilbronner Strasse 74
70191 Stuttgart
Deutschland
+49  711  61942-0 (Phone)
+49 711 61942-61  (Fax)
Kontakt

Wie können wir Ihnen helfen?

  • Benötigen Sie Unterstützung bei der Produktauswahl oder wünschen Sie eine technische Beratung? Kontaktieren Sie unsere Experten.
Frage stellen

Sie möchten ein Produktmuster?

Hier können Sie ein Produktmuster anfordern.

Muster anfordern

Mehr Produkte

Bitte wählen Sie eine Anwendung um Ihnen passende Produkte anzeigen zu können.

Bestellen

Meine Medien


Meine Favoriten

Meine Produkte